Operator rounds
Operator rounds checklist
A starting route for a plant operator round: pumps, motors, an air compressor, heat exchangers, tanks and housekeeping, with readings against limits and a note for every abnormal finding.
- How often
- Every shift
- Who
- Operator
- Time
- About 30 min
- Items
- 25
Download this checklist
Free, no sign-up
Before you use it
- Build each round from the equipment on the route and the ways it fails. Delete what does not apply, add your own equipment and put the checks in walking order.
- Give every reading a normal range from the manufacturer, the process design or the equipment’s own history, and decide what happens when a reading is outside it.
Pumps
- 1Checkpoint scan
Scan the pump’s tag
- 2Pass / fail
No seal leakage
- 3Pass / fail
No unusual noise or vibration
- 4Reading· °C or °F
Bearing housing temperature
By touch or infrared thermometer. Set the limits from the manufacturer’s manual and your normal operating range.
- 5Reading· bar or psi
Suction pressure
Set the limits from the manufacturer’s manual and your normal operating range.
- 6Reading· bar or psi
Discharge pressure
Set the limits from the manufacturer’s manual and your normal operating range.
- 7Pass / fail
Coupling guard in place
Motors
- 8Pass / fail
No unusual noise or smell of hot insulation
- 9Pass / fail
Cooling fins and fan cover clear
- 10Reading· A
Motor current
Where a local meter is fitted.
Air compressor
- 11Checkpoint scan
Scan the compressor’s tag
- 12Reading· bar or psi
Discharge pressure
Set the limits from the manufacturer’s manual and your normal operating range.
- 13Reading· °C or °F
Discharge temperature
Set the limits from the manufacturer’s manual and your normal operating range.
- 14Pass / fail
Oil level in the sight glass
- 15Pass / fail
Condensate drains working
Heat exchangers
- 16Reading· °C or °F
Inlet temperature
Set the limits from the manufacturer’s manual and your normal operating range.
- 17Reading· °C or °F
Outlet temperature
Set the limits from the manufacturer’s manual and your normal operating range.
- 18Pass / fail
No leaks at heads and flanges
Tanks and containment
- 19Reading· %
Tank level
Set the limits from the manufacturer’s manual and your normal operating range.
- 20Pass / fail
No leaks; bund drain valve closed
Housekeeping and safety
- 21Pass / fail
Guards in place, drains closed, labels legible
- 22Pass / fail
No spills; lighting working
- 23Photo
Photo of any abnormal finding
- 24Note
Abnormal findings and who was told
- 25Signature
Operator
Download this checklist
Free, no sign-up
Read more
Field types in this template
- Checkpoint scan
- Pass / fail
- Reading
- Photo
- Note
- Signature
In Vardian, readings are checked against their limits as they are entered, and photos and signatures attach to the check itself.
From the sheet to the round
Build a template as a Vardian form, and each line becomes a checkpoint that knows its limit.
Animation: a paper checklist line, compressor discharge pressure with a blank for the reading in bar, becomes a Vardian checkpoint with a limit of 7.0 to 8.5 bar. Scanning the compressor's NFC tag verifies the checkpoint, a reading of 9.1 bar is flagged out of range, and a work order is created from it.