Inspections

Pallet rack inspection checklist

A routine check of each run of pallet racking: load signs and loads, uprights and bracing, base plates and anchors, beams, connectors and safety locks, and pallet placement, with each finding located by bay and level and a result that offloads a damaged bay.

How often
Weekly, and after any reported impact
Who
Warehouse supervisor or designated rack inspector
Time
About 15 min
Items
21
Set it up in Vardian

Have your own paper version? A photo of it is enough for Vardian AI to draft the form. Photo-to-form →

Before you use it

  • A general checklist. It makes no claim about what any regulation requires. Load ratings, damage limits and repair methods come from the rack manufacturer and your site’s racking procedure; put those figures in before you use it.
  • Inspect one run at a time and record the bay and level of every finding. Grade damage the way your racking procedure does, for example monitor, repair or offload now. A damaged bay that stays loaded while it waits for repair is the case to avoid, so the result records whether the bay was offloaded and tagged.
  • Ask truck drivers to report every impact, not only the ones that leave visible damage, and check the area after each report. One record per run: scan the run’s tag, photograph each finding, and a damaged component becomes a work order with an owner.

Rack

  1. 1

    Scan the rack run tag

    Checkpoint scan
  2. 2

    Aisle, run and bays inspected

    Note

Loads and signs

  1. 3

    Load capacity sign present and legible

    Pass / fail
  2. 4

    Loads within the posted capacity

    Pass / fail
  3. 5

    Pallets seated squarely on both beams, with overhang as the procedure allows

    Pass / fail
  4. 6

    Pallets undamaged: no broken boards resting on the beams

    Pass / fail
  5. 7

    Loads stable and not leaning; nothing stored on top of the rack beyond its design

    Pass / fail

Uprights and frames

  1. 8

    Uprights plumb and not bent, dented, twisted or split

    Pass / fail
  2. 9

    Frame bracing not bent, loose or missing

    Pass / fail
  3. 10

    Base plates present, with anchors fitted and tight

    Pass / fail
  4. 11

    Upright protectors and end-of-aisle guards in place and undamaged

    Pass / fail

Beams and connectors

  1. 12

    Beams not bent, dented or visibly sagging under load

    Pass / fail
  2. 13

    Beam connectors fully seated, with no cracked welds or deformed hooks

    Pass / fail
  3. 14

    Safety locks or beam clips fitted at every connector

    Pass / fail
  4. 15

    Row spacers, wall ties, decking and pallet supports in place as designed

    Pass / fail

Damage found

  1. 16

    Location of damage: bay and level

    Note
  2. 17

    Damage grade

    None · Monitor · Repair · Offload now

    Choice
  3. 18

    Largest upright or beam deflection measured

    Compare with the rack manufacturer’s damage limits.

    Reading· in or mm
  4. 19

    Photo of the damage

    Photo

Result

  1. 20

    Result

    Fit for use · Repair work order raised · Bay offloaded and tagged until repaired

    Choice
  2. 21

    Inspector

    Signature

Field types in this template

  • Checkpoint scan
  • Note
  • Pass / fail
  • Choice
  • Reading
  • Photo
  • Signature

In Vardian, readings are checked against their limits as they are entered, and photos and signatures attach to the check itself.

From the sheet to the round

Build a template as a Vardian form, and each line becomes a checkpoint that knows its limit.

Animation: a paper checklist line, compressor discharge pressure with a blank for the reading in bar, becomes a Vardian checkpoint with a limit of 7.0 to 8.5 bar. Scanning the compressor's NFC tag verifies the checkpoint, a reading of 9.1 bar is flagged out of range, and a work order is created from it.

Run this checklist on the round

We'll set it up in Vardian with your checkpoints and limits during a demo.